Air and water pollution control., FX Trading, Macroeconomics

Thursday, 29 January 2009

How to convert Fahrenheit to Celsius degrees.

These days I was invited to flick through project for installation which incinerates wastes. The company which developed this project is from USA and I was very disappointed that most of the temperature currencies in the papers were in Fahrenheit. It is normal of course for people who live in other side of Atlantic Ocean but for most of the Europeans this digits are totally useless.

So let’s see how to convert from Fahrenheit to Celsius. The formula is very simple:


[0C] = ([0F] – 32) x (5/9)

One example f course

If [0F]= 32 then [0C] = (32-32) x (0.555)= 0 0C

The easiest way to remember this is when you see the value in F just deduct it with 32 and then divide the value by 0.555 or 5/9. It is not so correct but always works.

There is a very interesting fact to know that when you have temperature - 40 0F
the value in the Celsius is the same - 40 0C, but of course everything could be described with mathematics.

Here some web resources for on line converting.

Converter which I made

Interactive Thermometer - funny tool


Tuesday, 2 December 2008

ppm - mg/m3 calculator

I have prepared simple calculator for those who want to make a one or three calculations and to convert from ppm to mg/m3. In Google docs I put three sheets one for ppm to mg/m3 other to be easy calculating the molecular mass of the compound and third is to convert from m3 to Nm3.


Here are the sheets

Thursday, 16 October 2008

How to convert from m3 to Nm3?

Many times when you see the different concentrations of any polluters you may see it in mg/m3. For people who are not familiar with terminology this could be a little bit disturbing because some norms and limits are granted in mg/Nm3 which in some cases could be totally differen t.Where is the difference in this upper case N? N means Normal and according to International Union of Pure and Applied Chemistry and their site these standard conditions are temperature 273.15 K (C) and pressure 10^5 Pascal’s.

And what we should to do if have a concentration of 300 mg/m3 and limit of 150 mg/Nm3. Is it possible to reach the norm and even to outrun it? Yes in some cases it is possible but not in any of course. We can look our concentration and just to imagine that this concentration had measured in some chimney where the smoke gases became from furnace with temperature of 850 – 950 (Klaus process for example). And you have measured something like:

T (average): 650 0C

P (average): - 3 mm Hg

To = 273 K – this is normal temperature – 0 0C

Po = 760 mm Hg – 1 atm.

Other common measured parameter is a flow of smoke gases which is possible to be something like 130 000 m3

Then from these we are able to find some coefficient (let’s name it - K)

K = (To * P)/( Po *T) = [273*(760-3)]/[760*(273+650)]= 0.29

Now we should convert 130 000 m3/h * 0.29 = 37 700 Nm3

See how low are now these – round three times less than before. If we have measured the humidity in the chimney gases in percent then we also should remove this. It happens at this pattern:

If humidity is 5 % for example so then 37 700 Nm3 must multiple to this 5% and

37 700 * 0.05 = 1 885 Nm3 and

37 700 - 1 885 = 35 815 Nm3

At the end from 130 000 m3 we receive 35 815 Nm3 of chimney gases.

Monday, 15 September 2008

Vacancy in Canada

Yes!
I was in Canada for three weeks. Since 28 August to 16 September. It was wonderful experience. I have visited the Niagara and the capital of Canada - Ottawa. You are able to see some pictures

here.

I think they should be a most detailed than me.

And I promise in next my topic I will explain "How to convert from m3 to Nm3" and so on...

Wednesday, 13 August 2008

How to convert ppm to mg/m3

According to BIPM(Bureau International des Poids et Mesures) “ppm” is “The term "ppm", meaning 10–6 relative value, or 1 in 106, or parts per million, is also used. This is analogous to the meaning of percent as parts per hundred”

According to Wikipedia “ppm” is “"Parts-per" notation is used, especially in science and engineering, to denote relative proportions in measured quantities; particularly in low-value (high-ratio) proportions at the parts-per-million (ppm), parts-per-billion (ppb), and parts-per-trillion (ppt) level.”

I think one example will be more clear. These days when everyone talks for ecology we in EU know that there is a limits of the sulfur contains in the liquid fuels. In the EU since 2007 the contain of sulfur shall not exceed 50 ppm(Euro IV). And from 2009 it must be 10 ppm.

What this digits mean actually – if you burn one litter of diesel then you will burn and 50 ppm of sulfur or 50 parts from all million. This means that you will burn 50 milliliters of sulfur! Of course the sulfur is not liquid – the stuff sulfur is a yellow crystal and it melt on 115.21 degrees. So it is impossible to be liquid in the diesel. This shows us that the ppm measurement is not so correct in when we talk about stuffs with different states – liquid and crystal.

Let see how the ppm is used in gases from chimneys and how it is used. Years ago when I have started to learn about measuring of pollutions in chimney gases everything was in mg/m3 or milligrams per cubic meter. This mean mass in volume which is also strange because we talk about gases and their masses differ and depends from temperatures and pressure. Many of the limits are given in these measurement units and if you saw the limits in EU, UK or even Bulgaria every limits are in mg/m3. For example in UK the limits of NOx in chimney gases on appliances which are new and work with liquid fuels is 450 mg/m3.

So how we should work to transfer ppm to mg/m3 at first let look for example when we have concentration of 35 ppm SO2. This mean that in one cubic meter we have 1 000 000 cubic centimeters. Then if we have 35 ppm this means that in one cubic meter there is 35 cubic centimeters of sulfur dioxide – 35 cm3/m3. Now we must find how the weight of these 35 cm3 is. And we have 25 degrees and 1 atm. pressure. From equation of Klapeyron

ρ = (M/22.4)*(ToP/PoT) – this give us a density of the gases in different temperature and pressure.
Where:
M – molecular mass of the stuff
To – normal temperature – 273K
Po – normal pressure 1.03 kg/cm2
T – measured temperature
P – measured pressure

Then in 25 Celsius degrees and 1 atm. the equitation will be

ρ = (64/22.4)*(273*1.03/1.03*298)
ρ = 2.85*0.916 = 2.617 kg/m3

So we have found the density of the 35 cubic centimeters of sulfur dioxide and it is 2.617 kg/m3. Now we could find how is the mass of sulfur dioxide in this 35 cm3:

1.35 cm3/m3 can be present as 35 x 10-6 m3/m3 = 0.000035 m3/m3
2.2.617 kg/m3 = 2 617 000 mg/m3
3.Then 2 617 000 mg/m3 * 0.000035 m3/m3= 91.56 mg/m3 sulfur dioxide


There is a simple way to calculate this here is the formula:


Xppm=(Ymg/m3*24.45)/(molecular weight)
Xmg/m3=(Xppm*molecular weight)/(24.45)
You should change the needed values.

And if you are so lazy try online converter here.